FIXING
SCHEME
Reinforcement of the fixing of the
hinges is provided by 35mm longitudinal steel strips positioned at the
top and the bottom of the panel inner face. These steel reinforcements
between the insulation core and the metal skin assure durable and long
term fixing of intermediate hinges and roller carriers without the
screws to penetrate through the metal sheets’ folds inside the
polyurethane foam. Tecsedo only recommends to utilize 15 mm fixing
screws. In case of a choice of longer screws by the door
manufacturer/installer, a pilot hole has to be mandatory drilled in
advance. Repeated opening and closing of the door is always assured as
is the excellent long-lasting resistance to weather conditions.
FINGERSAFE PANELS
The specific joint detail complies with European
Safety Standard EN 12604 and must be used on doors less than 2500mm in
height. Please note that drawings refer to nominal dimension of panels,
therefore production tolerances of the actual delivered panels have to
be considered for a correct positioning of the hinges and for a proper
articulation of the panels. We recommend to assemble some trial doors
at your own company before shipping doors to the first customers. Many
factors have also to be considered to judge implications for sufficient
clearances for door flashings and surround:
• Width of the door (e.g.: having residential doors usually an
horizontal positioning of the sections along the ceiling, there is
always a panel warping of some mm for its own weigth, to be reduced
with the utilization of Omega bracing bars, imperative for door span
wider than 4.5 m)
• Number and distance of hinges utilized
• Deformation of the door for heat dilatation (panel bow, depending
upon: a.- Temperature difference between inside and outside
temperature, b.- Orientation of Door, c.- External finish colour)
• Hinges tolerances
• Door settlement after several cycles done
|
|